Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 55
Filter
1.
Restorative Dentistry & Endodontics ; : 68-74, 2015.
Article in English | WPRIM | ID: wpr-105467

ABSTRACT

OBJECTIVES: This study examined the effects of additional acid etching on the dentin bond strength of one-step self-etch adhesives with different compositions and pH. The effect of ethanol wetting on etched dentin bond strength of self-etch adhesives was also evaluated. MATERIALS AND METHODS: Forty-two human permanent molars were classified into 21 groups according to the adhesive types (Clearfil SE Bond [SE, control]; G-aenial Bond [GB]; Xeno V [XV]; Beauti Bond [BB]; Adper Easy Bond [AE]; Single Bond Universal [SU]; All Bond Universal [AU]), and the dentin conditioning methods. Composite resins were placed on the dentin surfaces, and the teeth were sectioned. The microtensile bond strength was measured, and the failure mode of the fractured specimens was examined. The data were analyzed statistically using two-way ANOVA and Duncan's post hoc test. RESULTS: In GB, XV and SE (pH 0.05). In AU (pH = 3.2), additional etching increased the bond strength significantly (p < 0.05). When adhesives were applied to the acid etched dentin with ethanol-wet bonding, the bond strength was significantly higher than that of the no ethanol-wet bonding groups, and the incidence of cohesive failure was increased. CONCLUSIONS: The effect of additional acid etching on the dentin bond strength was influenced by the pH of one-step self-etch adhesives. Ethanol wetting on etched dentin could create a stronger bonding performance of one-step self-etch adhesives for acid etched dentin.


Subject(s)
Humans , Adhesives , Composite Resins , Dentin , Ethanol , Hydrogen-Ion Concentration , Incidence , Molar , Tooth
2.
Restorative Dentistry & Endodontics ; : 128-135, 2015.
Article in English | WPRIM | ID: wpr-137551

ABSTRACT

OBJECTIVES: This study evaluated the effects of the resin thickness on the microhardness and optical properties of bulk-fill resin composites. METHODS: Four bulk-fill (Venus Bulk Fill, Heraeus Kulzer; SDR, Dentsply Caulk; Tetric N-Ceram Bulk Fill, Ivoclar vivadent; SonicFill, Kerr) and two regular resin composites (Charisma flow, Heraeus Kulzer; Tetric N-Ceram, Ivoclar vivadent) were used. Sixty acrylic cylindrical molds were prepared for each thickness (2, 3 and 4 mm). The molds were divided into six groups for resin composites. The microhardness was measured on the top and bottom surfaces, and the colors were measured using Commission Internationale d'Eclairage (CIE) L*a*b* system. Color differences according to the thickness and translucency parameters and the correlations between the microhardness and translucency parameter were analyzed. The microhardness and color differences were analyzed by ANOVA and Scheffe's post hoc test, and a student t-test, respectively. The level of significance was set to alpha = 0.05. RESULTS: The microhardness decreased with increasing resin thickness. The bulk-fill resin composites showed a bottom/top hardness ratio of almost 80% or more in 4 mm thick specimens. The highest translucency parameter was observed in Venus Bulk Fill. All resin composites used in this study except for Venus Bulk Fill showed linear correlations between the microhardness and translucency parameter according to the thickness. CONCLUSIONS: Within the limitations of this study, the bulk-fill resin composites used in this study can be placed and cured properly in the 4 mm bulk.


Subject(s)
Humans , Fungi , Hardness , Venus
3.
Restorative Dentistry & Endodontics ; : 128-135, 2015.
Article in English | WPRIM | ID: wpr-137550

ABSTRACT

OBJECTIVES: This study evaluated the effects of the resin thickness on the microhardness and optical properties of bulk-fill resin composites. METHODS: Four bulk-fill (Venus Bulk Fill, Heraeus Kulzer; SDR, Dentsply Caulk; Tetric N-Ceram Bulk Fill, Ivoclar vivadent; SonicFill, Kerr) and two regular resin composites (Charisma flow, Heraeus Kulzer; Tetric N-Ceram, Ivoclar vivadent) were used. Sixty acrylic cylindrical molds were prepared for each thickness (2, 3 and 4 mm). The molds were divided into six groups for resin composites. The microhardness was measured on the top and bottom surfaces, and the colors were measured using Commission Internationale d'Eclairage (CIE) L*a*b* system. Color differences according to the thickness and translucency parameters and the correlations between the microhardness and translucency parameter were analyzed. The microhardness and color differences were analyzed by ANOVA and Scheffe's post hoc test, and a student t-test, respectively. The level of significance was set to alpha = 0.05. RESULTS: The microhardness decreased with increasing resin thickness. The bulk-fill resin composites showed a bottom/top hardness ratio of almost 80% or more in 4 mm thick specimens. The highest translucency parameter was observed in Venus Bulk Fill. All resin composites used in this study except for Venus Bulk Fill showed linear correlations between the microhardness and translucency parameter according to the thickness. CONCLUSIONS: Within the limitations of this study, the bulk-fill resin composites used in this study can be placed and cured properly in the 4 mm bulk.


Subject(s)
Humans , Fungi , Hardness , Venus
4.
Restorative Dentistry & Endodontics ; : 310-318, 2014.
Article in English | WPRIM | ID: wpr-92615

ABSTRACT

OBJECTIVES: This study examined the influence of the resin thickness on the polymerization of silorane- and methacrylate-based composites. MATERIALS AND METHODS: One silorane-based (Filtek P90, 3M ESPE) and two methacrylate-based (Filtek Z250 and Z350, 3M ESPE) composite resins were used. The number of photons were detected using a photodiode detector at the different thicknesses (thickness, 1, 2 and 3 mm) specimens. The microhardness of the top and bottom surfaces was measured (n = 15) using a Vickers hardness with 200 gf load and 15 sec dwell time conditions. The degree of conversion (DC) of the specimens was determined using Fourier transform infrared spectroscopy (FTIR). Scratched powder of each top and bottom surface of the specimen dissolved in ethanol for transmission FTIR spectroscopy. The refractive index was measured using a Abbe-type refractometer. To measure the polymerization shrinkage, a linometer was used. The results were analyzed using two-way ANOVA and Tukey's test at p < 0.05 level. RESULTS: The silorane-based resin composite showed the lowest filler content and light attenuation among the specimens. P90 showed the highest values in the DC and the lowest microhardness at all depth. In the polymerization shrinkage, P90 showed a significantly lower shrinkage than the rest two resin products (p < 0.05). P90 showed a significantly lower refractive index than the remaining two resin products (p < 0.05). CONCLUSIONS: DC, microhardness, polymerization rate and refractive index linearly decreased as specimen thickness linearly increased. P90 showed much less polymerization shrinkage compared to other specimens. P90, even though achieved the highest DC, showed the lowest microhardness and refractive index.


Subject(s)
Composite Resins , Ethanol , Hardness , Photons , Polymerization , Polymers , Refractometry , Spectroscopy, Fourier Transform Infrared , Spectrum Analysis
5.
Restorative Dentistry & Endodontics ; : 31-35, 2013.
Article in English | WPRIM | ID: wpr-217166

ABSTRACT

OBJECTIVES: This study compared the cyclic fatigue resistance of nickel-titanium (NiTi) files obtained in a conventional test using a simulated canal with a newly developed method that allows the application of constant fatigue load conditions. MATERIALS AND METHODS: ProFile and K3 files of #25/.06, #30/.06, and #40/.04 were selected. Two types of testing devices were built to test their fatigue performance. The first (conventional) device prescribed curvature inside a simulated canal (C-test), the second new device exerted a constant load (L-test) whilst allowing any resulting curvature. Ten new instruments of each size and brand were tested with each device. The files were rotated until fracture and the number of cycles to failure (NCF) was determined. The NCF were subjected to one-way ANOVA and Duncan's post-hoc test for each method. Spearman's rank correlation coefficient was computed to examine any association between methods. RESULTS: Spearman's rank correlation coefficient (rho = -0.905) showed a significant negative correlation between methods. Groups with significant difference after the L-test divided into 4 clusters, whilst the C-test gave just 2 clusters. From the L-test, considering the negative correlation of NCF, K3 gave a significantly lower fatigue resistance than ProFile as in the C-test. K3 #30/.06 showed a lower fatigue resistance than K3 #25/.06, which was not found by the C-test. Variation in fatigue test methodology resulted in different cyclic fatigue resistance rankings for various NiTi files. CONCLUSIONS: The new methodology standardized the load during fatigue testing, allowing determination fatigue behavior under constant load conditions.


Subject(s)
Androsterone , Fatigue
6.
The Journal of Advanced Prosthodontics ; : 479-484, 2013.
Article in English | WPRIM | ID: wpr-227895

ABSTRACT

PURPOSE: The aim of this study was to evaluate the effects of additional acid etching and curing mechanism (light-curing or self-curing) of a composite resin on the dentin bond strength and compatibility of one-step self-etching adhesives. MATERIALS AND METHODS: Sixteen human permanent molars were randomly divided into eight groups according to the adhesives used (All-Bond Universal: ABU, Clearfil S3 Bond: CS3), additional acid etching (additional acid etching performed: EO, no additional acid etching performed: EX), and composite resins (Filtek Z-250: Z250, Clearfil FII New Bond: CFNB). Group 1: ABU-EO-Z250, Group 2: ABU-EO-CFNB, Group 3: ABU-EX-Z250, Group 4: ABU-EX-CFNB, Group 5: CS3-EO-Z250, Group 6: CS3-EO-CFNB, Group 7: CS3-EX-Z250, Group 8: CS3-EX-CFNB. After bonding procedures, composite resins were built up on dentin surfaces. After 24-hour water storage, the teeth were sectioned to make 10 specimens for each group. The microtensile bond strength test was performed using a microtensile testing machine. The failure mode of the fractured specimens was examined by means of an optical microscope at x20 magnification. The data was analyzed using a one-way ANOVA and Scheffe's post-hoc test (alpha=.05). RESULTS: Additional etching groups showed significantly higher values than the no additional etching group when using All-Bond Universal. The light-cured composite resin groups showed significantly higher values than the self-cured composite resin groups in the Clearfil S3 Bond. CONCLUSION: The additional acid etching is beneficial for the dentin bond strength when using low acidic one-step self-etch adhesives, and low acidic one-step self-etch adhesives are compatible with self-cured composite resin. The acidity of the one-step self-etch adhesives is an influencing factor in terms of the dentin bonding strength and incompatibility with a self-cured composite resin.


Subject(s)
Humans , Adhesives , Collodion , Composite Resins , Dental Cements , Dentin , Dentin-Bonding Agents , Molar , Resin Cements , Tooth , Water
7.
Journal of Korean Academy of Conservative Dentistry ; : 108-113, 2011.
Article in English | WPRIM | ID: wpr-178062

ABSTRACT

OBJECTIVES: To determine the effect of the spectral output of single and dual-peak light emitting diode (LED) curing lights on the microhardness and color stability of commercial resin composites formulated with camphorquinone and alternative photoinitiators in combination. MATERIALS AND METHODS: Three light-polymerized resin composites (Z100 (3M ESPE), Tetric Ceram (Ivoclar Vivadent) and Aelite LS Posterior (Bisco)) with different photoinitiator systems were used. The resin composites were packed into a Teflon mold (8 mm diameter and 2 mm thickness) on a cover glass. After packing the composites, they were light cured with single-peak and dual-peak LEDs. The Knoop microhardness (KHN) and color difference (DeltaE) for 30 days were measured. The data was analyzed statistically using a student's t-test (p < 0.05). RESULTS: All resin composites showed improved microhardness when a third-generation dual-peak LED light was used. The color stability was also higher for all resin composites with dual-peak LEDs. However, there was a significant difference only for Aelite LS Posterior. CONCLUSIONS: The dual-peak LEDs have a beneficial effect on the microhardness and color stability of resin composites formulated with a combination of camphorquinone and alternative photoinitiators.


Subject(s)
Camphor , Composite Resins , Enzyme Multiplied Immunoassay Technique , Fungi , Glass , Light , Polytetrafluoroethylene
8.
Journal of Korean Academy of Conservative Dentistry ; : 66-71, 2011.
Article in English | WPRIM | ID: wpr-147596

ABSTRACT

This case report compared the effectiveness of resin infiltration technique (Icon, DMG) with microabrasion (Opalustre, Ultradent Products, Inc.) in management of white spot lesions. It demonstrates that although neither microabrasion nor resin infiltration technique can remove white spot lesions completely, resin infiltration technique seems to be more effective than microabrasion. Therefore resin infiltration technique can be chosen preferentially for management of white spot lesions and caution should be taken for case selection.


Subject(s)
Humans , Dental Caries , White People
9.
Journal of Korean Academy of Conservative Dentistry ; : 203-210, 2011.
Article in English | WPRIM | ID: wpr-19515

ABSTRACT

OBJECTIVES: The purpose of this study was to evaluate the effect of various application methods of one-step self-etch adhesives to microtensile resin-dentin bond strength. MATERIALS AND METHODS: Thirty-six extracted human molars were used. The teeth were assigned randomly to twelve groups (n = 15), according to the three different adhesive systems (Clearfil Tri-S Bond, Adper Prompt L-Pop, G-Bond) and application methods. The adhesive systems were applied on the dentin as follows: 1) The single coating, 2) The double coating, 3) Manual agitation, 4) Ultrasonic agitation. Following the adhesive application, light-cure composite resin was constructed. The restored teeth were stored in distilled water at room temperature for 24 hours, and prepared 15 specimens per groups. Then microtensile bond strength was measured and the failure mode was examined. RESULTS: Manual agitation and ultrasonic agitation of adhesive significantly increased the microtensile bond strength than single coating and double coating did. Double coating of adhesive significantly increased the microtensile bond strength than single coating did and there was no significant difference between the manual agitation and ultrasonic agitation group. There was significant difference in microtensile bonding strength among all adhesives and Clearfil Tri-S Bond showed the highest bond strength. CONCLUSIONS: In one-step self-etching adhesives, there was significant difference according to application methods and type of adhesives. No matter of the material, the manual or ultrasonic agitation of the adhesive showed significantly higher microtensile bond strength.


Subject(s)
Humans , Adhesives , Dentin , Dihydroergotamine , Molar , Resin Cements , Tooth , Ultrasonics , Water
10.
Journal of Korean Academy of Conservative Dentistry ; : 134-142, 2010.
Article in English | WPRIM | ID: wpr-70541

ABSTRACT

The purpose of this study was to evaluate the effect of Er,Cr:YSGG laser irradiation with hypersensitivity mode on microtensile bond strength of composite resin. Twenty extracted permanent molars were randomly assigned to six groups, according to the irradiation of Er,Cr:YSGG laser, adhesive system (Optibond FL or Clearfil SE bond) and application time of etchant (15 sec or 20 sec). Then composite resin was build up on each conditioned surface. The restored teeth were stored in distilled water at room temperature for 24 h and twelve specimens for each group were prepared. All specimens were subjected to microtensile bond strength and the fracture modes were evaluated. Also, the prepared dentin surface and laser irradiated dentin surface were examined under SEM. The results were as follows: 1. The microtensile bond strength of laser irradiated group was lower than that of no laser irradiated group. 2. Regardless of laser irradiation, the microtensile bond strength of Optibond FL was higher than that of Clearfil SE bond. And the microtensile bond strength of 20 sec etching group was higher than that of 15 sec etching group when using Optibond FL. 3. The SEM image of laser irradiated dentin surface showed prominent peritubular dentin, opened dentinal tubules and no smear layer.


Subject(s)
Adhesives , Dentin , Hypersensitivity , Molar , Resin Cements , Smear Layer , Tooth , Water
11.
Journal of Korean Academy of Conservative Dentistry ; : 445-452, 2010.
Article in Korean | WPRIM | ID: wpr-158031

ABSTRACT

OBJECTIVES: The aim of this study was to compare apical sealing ability and physical properties of MTA, MTA - AH-plus mixture (AMTA) and experimental Portland cement - Epoxy resin mixture (EPPC) for a development of a novel retro-filling material. MATERIALS AND METHODS: Forty-nine extracted roots were instrumented and filled with gutta-percha. Apical root was resected at 3 mm and the retro-filling cavity was prepared for 3 mm depth. Roots were randomly divided into 3 groups of 15 roots each. The retro-filling was done using MTA, AMTA, and EPPC as the groups divided. Four roots were used as control groups. After setting in humid condition for 24 hours, the roots were immersed in 1% methylene blue dye solution for 72 hours to test the apical leakage. After immersion, the roots were vertically sectioned and photos were taken to evaluate microleakage. Setting times were measured with Vicat apparatus and digital radiographs were taken to evaluate aluminum equivalent thickness using aluminum step wedge. The results of microleakage and setting time were compared between groups using one-way ANOVA and Scheffe's post-hoc comparison at the significance level of 95%. RESULTS: AMTA and EPPC showed less microleakage than MTA group (p < 0.05). AMTA showed the highest radio-opacity than other groups and the novel EPPC showed 5 mm aluminum thickness radio-opacity. EPPC showed the shortest initial and final setting times than other groups while the MTA showed the longest (p < 0.05). CONCLUSIONS: Under the condition of this study, the novel composite using Portland cement-Epoxy resin mixture may useful for retro-filling with the properties of favorable leakage resistance, radio-opacity and short setting time.


Subject(s)
Aluminum , Glutamates , Guanine , Gutta-Percha , Immersion , Methylene Blue , Pemetrexed
12.
Journal of Korean Academy of Conservative Dentistry ; : 479-485, 2010.
Article in English | WPRIM | ID: wpr-158027

ABSTRACT

OBJECTIVES: The aim of this study was to compare the push-out bond strengths of resin cement/fiber post systems to post space dentin using different application methods of resin cement. MATERIALS AND METHODS: Thirty extracted human premolars were selected and randomly divided into 3 groups according to the technique used to place the cement into root canal: using lentulo-spiral instrument (group Lentulo), applying the cement onto the post surface (group Direct), and injecting the material using a specific elongation tip (group Elongation tip). After shaping and filling of the root canal, post space was drilled using Rely-X post drill. Rely-X fiber post was seated using Rely-X Unicem and resin cement was light polymerized. The root specimens were embedded in an acrylic resin and the specimens were sectioned perpendicularly to the long axis using a low-speed saw. Three slices per each root containing cross-sections of coronal, middle and apical part of the bonded fiber posts were obtained by sectioning. The push-out bond strength was measured using Universal Testing Machine. Specimens after bond failure were examined using operating microscope to evaluate the failure modes. RESULTS: Push-out bond strengths were statistically influenced by the root regions. Group using the elongation tip showed significantly higher bond strength than other ways. Most failures occurred at the cement/dentin interface or in a mixed mode. CONCLUSIONS: The use of an elongation tip seems to reduce the number of imperfections within the self-adhesive cement interface compared to the techniques such as direct applying with the post and lentulo-spiral technique.


Subject(s)
Humans , Axis, Cervical Vertebra , Bicuspid , Collodion , Dental Pulp Cavity , Dentin , Hypogonadism , Light , Mandrillus , Mitochondrial Diseases , Ophthalmoplegia , Polymers , Resin Cements
13.
Journal of Korean Academy of Conservative Dentistry ; : 486-491, 2010.
Article in English | WPRIM | ID: wpr-158026

ABSTRACT

OBJECTIVES: This study examined the effect of 2% chlorhexidine on the microTBS of a direct composite restoration using one-step self-etch adhesives on human dentin. MATERIALS AND METHODS: Twenty-four extracted permanent molars were used. The teeth were assigned randomly to six groups (n = 10), according to the adhesive system and application of chlorhexidine. With or without the application of chlorhexidine, each adhesive system was applied to the dentin surface. After the bonding procedure, light-cure composite resin buildups were produced. The restored teeth were stored in distilled water at room temperature for 24 hours, and then cut and glued to the jig of the microtensile testing machine. A tensile load was applied until the specimen failed. The failure mode was examined using an operating microscope. The data was analyzed statistically using one-way ANOVA, Student's t-test (p < 0.05) and Scheffe's test. RESULTS: Regardless of the application of chlorhexidine, the Clearfil S3 Bond showed the highest microTBS, followed by G-Bond and Xeno V. Adhesive failure was the main failure mode of the dentin bonding agents tested with some samples showing cohesive failure. CONCLUSIONS: The application of 2% chlorhexidine did not affect the microTBS of the resin composite to the dentin using a one-step self-etch adhesive.


Subject(s)
Humans , Adhesives , Chlorhexidine , Dental Cements , Dentin , Dentin-Bonding Agents , Methacrylates , Molar , Resin Cements , Tooth , Water
14.
Journal of Korean Academy of Conservative Dentistry ; : 1-7, 2009.
Article in Korean | WPRIM | ID: wpr-44647

ABSTRACT

The purpose of this study was to compare the stress distributions of NiTi rotary instruments based on their cross-sectional geometries of triangular shape-based cross-sectional design, S-shaped cross-sectional design and modified rectangular shape-based one using 3D FE models. NiTi rotary files of S-shaped and modified rectangular design of cross-section such as Mtwo or NRT showed larger stress change while file rotation during simulated shaping. The stress of files with rectangular cross-section design such as Mtwo, NRT was distributed as an intermittent pattern along the long axis of file. On the other hand, the stress of files with triangular cross-section design was distributed continuously. When the residual stresses which could increase the risk of file fatigue fracture were analyzed after their withdrawal, the NRT and Mtwo model also presented higher residual stresses. From this result, it can be inferred that S-shaped and modified rectangular shape-based files were more susceptible to file fracture than the files having triangular shape-based one.


Subject(s)
Axis, Cervical Vertebra , Finite Element Analysis , Fractures, Stress , Hand
15.
Journal of Korean Academy of Conservative Dentistry ; : 8-19, 2009.
Article in English | WPRIM | ID: wpr-44646

ABSTRACT

The purpose of this study was to investigate the effects of four restorative materials under various occlusal loading conditions on the stress distribution at the CEJ of buccal, palatal surface and central groove of occlusal surface of endodontically treated maxillary second premolar, using a 3D finte element analysis. A 3D finite element model of human maxillary second premolar was endodontically treated. After endodontic treatment, access cavity was filled with Amalgam, resin, ceramic or gold of different mechanical properties. A static 500N forces were applied at the buccal (Load-1) and palatal cusp (Load-2) and a static 170N forces were applied at the mesial marginal ridge and palatal cusp simultaneously as centric occlusion (Load-3). Under 3-type Loading condition, the value of tensile stress was analyzed after 4-type restoration at the CEJ of buccal and palatal surface and central groove of occlusal surface. Excessive high tensile stresses were observed along the palatal CEJ in Load-1 case and buccal CEJ in Load-2 in all of the restorations. There was no difference in magnitude of stress in relation to the type of restorations. Heavy tensile stress concentrations were observed around the loading point and along the central groove of occlusal surface in all of the restorations. There was slight difference in magnitude of stress between different types of restorations. High tensile stress concentrations around the loading points were observed and there was no difference in magnitude of stress between different types of restorations in Load-3.


Subject(s)
Humans , Bicuspid , Ceramics , Finite Element Analysis , Tooth Cervix
16.
Journal of Korean Academy of Conservative Dentistry ; : 69-79, 2009.
Article in English | WPRIM | ID: wpr-44639

ABSTRACT

The purpose of this study was to evaluate the influence of elastic modulus of restorative materials and the number of interfaces of post and core systems on the stress distribution of three differently restored endodontically treated maxillary second premolars using 3D FE analysis. Model 1, 2 was restored with a stainless steel or glass fiber post and direct composite resin. A PFG or a sintered alumina crown was considered. Model 3 was restored by EndoCrown. An oblique 500 N was applied on the buccal (Load A) and palatal (Load B) cusp. The von Mises stresses in the coronal and root structure of each model were analyzed using ANSYS. The elastic modulus of the definitive restorations rather than the type of post and core system was the primary factor that influenced the stress distribution of endodontically treated maxillary premolars. The stress concentration at the coronal structure could be lowered through the use of definitive restoration of high elastic modulus. The stress concentration at the root structure could be lowered through the use of definitive restoration of low elastic modulus.


Subject(s)
Aluminum Oxide , Bicuspid , Crowns , Elastic Modulus , Finite Element Analysis , Glass , Stainless Steel
17.
Journal of Korean Academy of Conservative Dentistry ; : 397-405, 2009.
Article in English | WPRIM | ID: wpr-31985

ABSTRACT

This study compared the effect of an activator, intermediate bonding resin and low-viscosity flowable resin on the microtensile bond strength of a self-curing composite resin used with two-step total etching adhesives. Twenty extracted permanent molars were used. The teeth were assigned randomly to nine groups (n=10) according to the adhesive system and application of additional methods (activator, intermediate adhesive, flowable resin). The bonding agents and additional applications of each group were applied to the dentin surfaces. Self-curing composite resin buildups were made for each tooth to form a core, 5mm in height. The restored teeth were then stored in distilled water at room temperature for 24h before sectioning. The microtensile bond strength of all specimens was examined. The data was analyzed statistically by one-way ANOVA and a Scheffe's test. The application of an intermediate bonding resin (Optibond FL adhesive) and low-viscosity flowable resin (Tetric N-flow) produced higher bond strength than that with the activator in all groups. Regardless of the method selected, Optibond solo plus produced the lowest microTBS to dentin. The failure modes of the tested dentin bonding agents were mostly adhesive failure but there were some cases showed cohesive failure in the resin.


Subject(s)
Adhesives , Dentin , Dentin-Bonding Agents , Molar , Resin Cements , Tooth , Water
18.
Korean Journal of Dermatology ; : 904-910, 2009.
Article in Korean | WPRIM | ID: wpr-16927

ABSTRACT

BACKGROUND: An odontogenic sinus tract draining to the skin is the most common type of cutaneous fistula that occurs on the face. This lesion can be a diagnostic challenge to clinicians who are not familiar with cutaneous fistula since many patients with an odontogenic sinus tract draining to the skin do not have any symptom such as toothache. OBJECTIVE: Our purpose was to determine the characteristic features of an odontogenic sinus tract draining to the skin. METHODS: Eleven patients who presented with an odontogenic sinus tract draining to the skin at the Dermatologic Department of Pusan National University Hospital during the last ten years were enrolled in this study. We reviewed all the medical records of the patients. RESULTS: The mean age was 51.8 years. The male to female ratio was 1.2:1. Nine patients (82%) had lesions on their chins or the mandibular region. The most common tooth with endodontic infection was the lower first premolar tooth (36%), and the most common clinical feature was pyogenic granuloma-like solitary papule (64%). The panoramic view showed radiolucent periapical abscesses in all the patients. Skin biopsy showed chronic granulomatous inflammation, and fistular tracts were present in three patients. Only 1 of 11 patients (9%) had toothache, and two patients had prior therapies for prosthetic dentures or caries, respectively. Nine patients (82%) were treated ineffectively, and their first visit was to adermatologic clinic (91%) or an otolaryngologic clinic (9%). After the diagnosis of odontogenic sinus tract draining to the skin, eight patients (73%) were treated completely by root canal therapy or extraction of teeth. CONCLUSION: In this study, most patients had no toothache or history of dental disease, and they were treated inappropriately, even in dermatologic clinics. The results of this study will help reduce the incidence of inappropriate management for odontogenic sinus tract draining to the skin at dermatologic departments.


Subject(s)
Female , Humans , Male , Bicuspid , Biopsy , Chin , Cutaneous Fistula , Dentures , Incidence , Inflammation , Medical Records , Periapical Abscess , Root Canal Therapy , Skin , Stomatognathic Diseases , Tooth , Toothache
19.
Journal of Korean Academy of Conservative Dentistry ; : 208-214, 2009.
Article in Korean | WPRIM | ID: wpr-21550

ABSTRACT

The purpose of this study was to compare the dye leakage of MTA (mineral trioxide aggregate) apical plug produced by two orthograde placement techniques (hand condensation technique and ultrasonically assisted hand condensation technique). To simulate straight canal, 60 transparent acrylic blocks with straight canal were fabricated. These transparent acrylic blocks were divided into 2 groups (Group C; hand condensation technique (HC) and Group U; ultrasonically assisted hand condensation technique (UAHC)) of 30 blocks with each MTA application method. Each group was divided into 2 subgroups (n = 15) with different canal size of #70 (subgroup C70 and subgroup U70) and #120 (subgroup C120 and subgroup U120). After apical plug was created, a wet paper point was placed over the MTA plug and specimen was kept in a humid condition at room temperature to allow MTA to set. After 24 hours, remaining canal space was backfilled using Obtura II. All specimens were transferred to floral form socked by 0.2% rhodamine B solution and stored in 100% humidity at room temperature. After 48 hours, resin block specimens were washed and scanned using a scanner. The maximum length of microleakage was measured from the scanned images of four surfaces of each resin block using Photoshop 6.0. Statistical analysis was performed with Mann-Whitney U test. Group U of UAHC had significantly lower leakage than Group C of HC in #70-size canal (subgroup U70) (p < 0.05).


Subject(s)
Glutamates , Guanine , Hand , Humidity , Rhodamines , Root Canal Filling Materials , Ultrasonics , Pemetrexed
20.
Journal of Korean Academy of Conservative Dentistry ; : 184-197, 2008.
Article in English | WPRIM | ID: wpr-77638

ABSTRACT

This study was to investigate the influence of combining composite resins with different elastic modulus, and occlusal loading condition on the stress distribution of restored notch-shaped non-carious cervical lesion using 3D finite element (FE) analysis. The extracted maxillary second premolar was scanned serially with Micro-CT. The 3D images were processed by 3D-DOCTOR. ANSYS was used to mesh and analyze 3D FE model. A notch-shaped cavity was modeled and filled with hybrid, flowable resin or a combination of both. After restoration, a static load of 500N was applied in a point-load condition at buccal cusp and palatal cusp. The stress data were analyzed using analysis of principal stress. Results showed that combining method such that apex was restored by material with high elastic modulus and the occlusal and cervical cavosurface margin by small amount of material with low elastic modulus was the most profitable method in the view of tensile stress that was considered as the dominant factor jeopardizing the restoration durability and promoting the lesion progression.


Subject(s)
Bicuspid , Chimera , Composite Resins , Elastic Modulus , Finite Element Analysis
SELECTION OF CITATIONS